Toroidal transformers

Toroidal transformers

NAME:Toroidal transformers
  • Product Description
  • Toroidal Transformer
    This kind of toroidal transformer is widely apply to Electronic Control ,Cable TV & Digital TV ,HI-FI (Audio-Video) Equipment ,Medical Equipment ,New Electric Power Supply ,Electronic Meter & Apparatus .With their good price ,reliable Performance and Safety,High Efficiency,they sell well all over the world.
  • Basic Data
    Capacity: 20VA-5000VA
    Phase: Single
    Input: AC Power with Voltages of Various Countries
    Output: AC Current,Voltage,According to Customers Requirements
    Frequency: 50-60Hz
    Voltage Regulation: 12%-3%
    Manufacture Standard: GB/T15290-94,GB/19212-2006,GB2828-2829-87
    Insulation Class: B,130 Celsius Degree; E,120 Celsius Degree
    Temperature-rise: ≤85 Celsius Degree
  • Material
    Core: High quality cold grain silicon sheets inserted by machine,annealed by advanced vacuum annealing furnaces to improve electronic data
    Bobbin: Excellent Anti-combustion
    Wire Materials:
    1. Copper,Aluminum,Aluminum Clad Copper.
    2. The size of transformer total in Aluminum is larger than which total in Copper.
    3. Aluminum instead of Copper Cost Save: 13%-35%/PCgh
  • Comparison on Transformer with Toroidal,EI,R,CD Shape Core
    Since 1995,we have been playing a leading role to replace the types of R,CD,EI with toroidal type for our customers from each part of the world.
    Core EI,R & CD Toroidal
    Dimension Not Adjustable Adjustable
    Performance Average Better
    Reliability Average Better
    Price Expensive 10%-30% Cost Saved
  • Operating environment
    1)Temp.: The ambient temperature can not over +40 Degree Celsuis.
    2)Altitude: Mounting location can not exceed the altitude of 2000m
    3)Relative humidity: Maximum 90%
    4)The site not attack by rain and snow
    5)The medium which no explosion danger,no corroding metal,no electrical breakdown
  • Testing Items:
    No-load Test(No-load Current,No-load Voltage,No-load Loss)
    Load Test (Load Voltage,Temperature-rise)
    Inductive Voltage Test
    DC Resistance Test
    Safety Test
  •   Model   Power Out size(mm) Install screw(mm) Weight
    H OD M Kg
    HB-20 20 40 75 6*50 0.6
    HB-30 30 40 82 6*50 0.7
    HB-40 40 40 90 6*50 0.85
    HB-50 50 45 90 8*55 1.05
    HB-60 60 45 95 8*55 1.2
    HB-80 80 45 100 8*55 1.45
    HB-100 100 50 100 8*60 1.6
    HB-120 120 50 110 8*60 1.95
    HB-150 150 55 110 8*65 2.25
    HB-200 200 60 110 8*70 2.6
    HB-250 250 70 110 8*80 2.9
    HB-300 300 70 120 8*80 3.4
    HB-400 400 75 125 8*85 4
    HB-500 500 80 130 8*90 4.5
    HB-600 600 85 135 8*95 5.5
    HB-800 800 95 135 10*105 6.5
     HB-1000 1000 100 145 10*110 8.2
     HB-1500 1500 100 160 10*110 10.4
     HB-2000 2000 100 175 10*110 13.3
     HB-2500 2500 110 185 10*120 15.5
     HB-3000 3000 110 190 10*120 16.8
     HB-3500 3500 110 195 12*120 18.2
     HB-4000 4000 115 195 12*125 19