NAME:B9-200A Hall Current Sensor
  • ELECTRICAL  DATA

Nominal current 200 A
Measuring range 300 A
Turns ratio 1:2000  
Measuring resistance with±12V  @±200Amax   0(min)  26(max) Ω
@±250Amax    0(min)  4(max) Ω
with±15V  @±200Amax   0(min)  56(max) Ω
@±300Amax    0(min)  8(max) Ω
Supply voltage ±15±5% V
Nominal analogue
output current
100±0.5% mA
Accuracy at +25℃ 0.1 %
Galvanic isolation 50(60)HZ,1min,3 KV

 

  • ACCURACY  DYNAMIC  PERFORMANCE

Zero offset current ±0.1 mA
Thermal drift of 
offset current
-40℃~+85℃±0.5 mA
Response time <1 µs
Linearity ≤0.1 %FS
Bandwidth(-3dB) DC…100 KHz
di/dt >200 A/μs

 

  • GENERAL  DATA

Secondary
internal  resistance
80 Ω
Operating temperature -40~+85
Storage temperature -55~+125

 

  • Dimensions(mm)

  • Operating instructions
  • 1.It is positive when Ip flows in the direction of the arrow.
  • 2.Temperature of the primary conductor should not exceed 100 ℃。
  • 3.Dynamic performances (di/dt and the response time) are best with a single bar completely filling the primary hole.
  • 4.In order to achieve the best magnetic coupling,the primary windings have to be wound over the top edge of the device